Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Chemosphere ; 357: 142075, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38648985

RESUMO

Pesticides are considered one of the main sources of contamination of surface waters, especially in rural areas highly influenced by traditional agricultural practices. The objective of this work was to evaluate the impact caused by pesticides and their transformation products (TPs) related to olive groves in surface waters with strong agricultural pressure. 11 streams were monitored during four sampling campaigns over 2 years. A solid-phase extraction, followed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) analysis was used in the quantitative target approach, with more than 70 validated compounds. Target method was combined with a suspect screening strategy involving more than 500 pesticides and TPs, using ultra-high-performance liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS) to identify additional pesticides and TPs out of the scope of analysis. A total of 43 different compounds were detected with the target method. The herbicide MCPA was present in all samples and at the highest concentration (1260 ng L-1), followed by the fungicide carbendazim (1110 ng L-1), and the herbicide chlorotoluron (706 ng L-1). The suspect screening strategy revealed the presence of 7 compounds out of the target analysis (1 pesticide and 6 TPs). 6 analytes were confirmed with the analytical standards. Semi-quantification results revealed that TPs exhibited higher concentrations than their corresponding parent compounds, indicating higher persistency. Some small streams showed a comparable number of pesticides and concentrations to the most polluted large river. The determined pesticide and TPs concentrations represented an estimated environmental hazard in almost all sampling sites under study. This work underscores the importance of including pesticide TPs and small streams impacted by extensive agricultural activities in water quality monitoring programs.

2.
Talanta ; 274: 126011, 2024 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-38574537

RESUMO

In this article, we have studied the potential of flexible microtube plasma (FµTP) as ionization source for the liquid chromatography high-resolution mass spectrometry detection of non-easily ionizable pesticides (viz. nonpolar and non-ionizable by acid/basic moieties). Phthalimide-related compounds such as dicofol, dinocap, o-phenylphenol, captan, captafol, folpet and their metabolites were studied. Dielectric barrier discharge ionization (DBDI) was examined using two electrode configurations, including the miniaturized one based on a single high-voltage (HV) electrode and a virtual ground electrode configuration (FµTP), and also the two-ring electrode DBDI configuration. Different ionization pathways were observed to ionize these challenging, non-easily ionizable nonpolar compounds, involving nucleophilic substitutions and proton abstraction, with subtle differences in the spectra obtained compared with APCI. An average sensitivity increase of 5-fold was attained compared with the standard APCI source. In addition, more tolerance with matrix effects was observed in both DBDI sources. The importance of the data reported is not just limited to the sensitivity enhancement compared to APCI, but, more notably, to the ability to effectively ionize nonpolar, late-eluting (in reverse-phase chromatography) non-ionizable compounds. Besides o-phenylphenol ([M - H]-), all the parent species were efficiently ionized through different mechanisms involving bond cleavages through the effect of plasma reagent species or its combination with thermal degradation and subsequent ionization. This tool can be used to figure out overlooked nonpolar compounds in different environmental samples of societal interest through non-target screening (NTS) strategies.

3.
Anal Chem ; 96(13): 5289-5297, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38507224

RESUMO

Paper spray mass spectrometry (PS-MS) has evolved into a promising tool for monitoring reactions in thin films and microdroplets, known as reactive PS, alongside its established role in ambient and direct ionization. This study addresses the need for rapid, cost-effective methods to improve analyte identification in biofluids by leveraging reactive PS-MS in clinical chemistry environments. The technique has proven effective in derivatizing target analytes, altering hydrophobicity to enhance elution and ionization efficiency, and refining detection through thin-film reactions on paper, significantly expediting reaction rates by using amino acids (AAs) as model analytes. These molecules are prone to interacting with substrates like paper, impeding elution and detection. Additionally, highly abundant species in biofluids, such as lipids, often suppress AA ionization. This study employs the Schiff base (SB) reaction utilizing aromatic aldehydes for AA derivatization to optimize reaction conditions time, temperature, and catalyst presence and dramatically increasing the conversion ratio (CR) of formed SB. For instance, using leucine as a model AA, the CR surged from 57% at room temperature to 89% at 70 °C, with added pyridine during and after 7.5 min, displaying a 43% CR compared to the bulk reaction. Evaluation of various aromatic aldehydes as derivatization agents highlighted the importance of specific oxygen substituents for achieving higher conversion rates. Furthermore, diverse derivatization agents unveiled unique fragmentation pathways, aiding in-depth annotation of the target analyte. Successfully applied to quantify AAs in human and rat plasma, this reactive PS-MS approach showcases promising potential in efficiently detecting conventionally challenging compounds in PS-MS analysis.


Assuntos
Aminoácidos , Bases de Schiff , Humanos , Animais , Ratos , Espectrometria de Massas/métodos , Aminas , Aldeídos/análise
4.
Anal Chem ; 95(50): 18370-18378, 2023 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-37902451

RESUMO

The present study investigated the potential for solvent-assisted laser desorption coupled with flexible microtube plasma ionization mass spectrometry (SALD-FµTP-MS) as a rapid analytical technique for direct analysis of surface-deposited samples. Paper was used as the demonstrative substrate, and an infrared hand-held laser was employed for sample desorption, aiming to explore cost-effective sampling and analysis methods. SALD-FµTP-MS offers several advantages, particularly for biofluid analysis, including affordability, the ability to analyze low sample volumes (<10 µL), expanded chemical coverage, sample and substrate stability, and in situ analysis and high throughput potential. The optimization process involved exploring the use of viscous solvents with high boiling points as liquid matrices. This approach aimed to enhance desorption and ionization efficiencies. Ethylene glycol (EG) was identified as a suitable solvent, which not only improved sensitivity but also ensured substrate stability during analysis. Furthermore, the addition of cosolvents such as acetonitrile/water (1:1) and ethyl acetate further enhanced sensitivity and reproducibility for a standard solution containing amphetamine, imazalil, and cholesterol. Optimized conditions for reproducible and sensitive analysis were determined as 1000 ms of laser exposure time using a 1 µL solvent mixture of 60% EG and 40% acetonitrile (ACN)/water (1:1). A mixture of 60% EG and 40% ACN/water (1:1) resulted in signal enhancements and relative standard deviations of 12, 20, and 13% for the evaluated standards, respectively. The applicability of SALD-FµTP-MS was further evaluated by successfully analyzing food, water, and biological samples, highlighting the potential of SALD-FµTP-MS analysis, particularly for thermolabile and polarity diverse compounds.


Assuntos
Lasers , Água , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Solventes , Reprodutibilidade dos Testes , Acetonitrilas
5.
J Am Soc Mass Spectrom ; 34(6): 1145-1152, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37231669

RESUMO

Dielectric barrier discharges (DBD) are highly versatile plasma sources for forming ions at atmospheric pressure and near ambient temperatures for the rapid, direct, and sensitive analysis of molecules by mass spectrometry (MS). Ambient ion sources should ideally form intact ions, as in-source fragmentation can limit sensitivity, increase spectral complexity, and hinder interpretation. Here, we report the measurement of ion internal energy distributions for the four primary classes of DBD-based ion sources, specifically DBD ionization (DBDI), low-temperature plasma (LTP), flexible microtube plasma (FµTP), and active capillary plasma ionization (ACaPI), in addition to atmospheric pressure chemical ionization (APCI) using para-substituted benzylammonium thermometer ions. Surprisingly, the average extent of energy deposited by the use of ACaPI (90.6 kJ mol-1) was ∼40 kJ mol-1 lower than the other ion sources (DBDI, LTP, FµTP, and APCI; 130.2 to 134.1 kJ mol-1) in their conventional configurations, and slightly higher than electrospray ionization (80.8 kJ mol-1). The internal energy distributions did not depend strongly on the sample introduction conditions (i.e., the use of different solvents and sample vaporization temperatures) or the DBD plasma conditions (i.e., maximum applied voltage). By positioning the DBDI, LTP, and FµTP plasma jets on axis with the capillary entrance to the mass spectrometer, the extent of internal energy deposition could be reduced by up to 20 kJ mol-1, although at the expense of sensitivity. Overall, the use of an active capillary-based DBD can result in substantially less fragmentation of ions with labile bonds than alternate DBD sources and APCI with comparably high sensitivity.

6.
Mass Spectrom Rev ; 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-37010157

RESUMO

In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analysed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimisation of the different analytical aspects that will condition the 2D-LC-MS performance. The presence of contaminants in food (food safety), the food quality and authenticity or the relationship between the beneficial effects of food and human health are some of the fields in which most of the 2D-LC-MS applications are mainly focused. Both heart-cutting and comprehensive applications are described and discussed in this review, highlighting the potential of 2D-LC-MS for the analysis of such complex samples.

7.
Mass Spectrom Rev ; 2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37056215

RESUMO

In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analyzed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimization of the different analytical aspects that will condition the 2D-LC-MS performance. The presence of contaminants in food (food safety), the food quality, and authenticity or the relationship between the beneficial effects of food and human health are some of the fields in which most of the 2D-LC-MS applications are mainly focused. Both heart-cutting and comprehensive applications are described and discussed in this review, highlighting the potential of 2D-LC-MS for the analysis of such complex samples.

8.
Anal Chem ; 95(2): 854-861, 2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36538370

RESUMO

Dielectric barrier discharge ionization (DBDI) is a versatile tool for small-molecule mass spectrometry applications, helping cover from polar to low polar molecules. However, the plasma gas-phase interactions are highly complex and have been scarcely investigated. The ionization mechanisms of plasmas have long been assumed to be somewhat similar to atmospheric pressure chemical ionization (APCI). Here, we evaluated the ionization mechanisms of a two-ring DBDI ion source, using different discharge gases to analyze vaporized liquid samples. Polycyclic aromatic hydrocarbons (PAHs) were used as model analytes to assess the mechanisms' dominance: protonation, [M + H]+, or radical ion species formation, [M]·+. In the present work, two different ionization trends were observed for APCI and DBDI during the PAH analysis; the compounds with proton affinities (PA) over 856 kJ/mol were detected as [M + H]+ when APCI was used as ionization source. Meanwhile, independently of the PA, DBDI showed the prevalence of charge exchange reactions. The addition of dopants in the gas-phase region shifted the ionization mechanisms toward charge exchange reactions, facilitating the formation of [M]·+ ion species, showing anisole a significant boost of the PAH radical ion species signals, over nine times for Ar-Prop-DBDI analysis. The presence of high-energy metastable atoms (e.g., HeM) with high ionization potentials (IE = 19.80 eV) did not show boosted PAH abundances or extensive molecule fragmentation. Moreover, other species in the plasma jet region with closer and more appropriate IE, such as N2 B3Πg excited molecules, are likely responsible for PAH Penning ionization.


Assuntos
Hidrocarbonetos Policíclicos Aromáticos , Humanos , Hidrocarbonetos Policíclicos Aromáticos/análise , Espectrometria de Massas/métodos
9.
J Sep Sci ; 45(16): 3105-3114, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35801641

RESUMO

Dielectric barrier discharge ionization has gained attention in the last few years due to its versatility and the vast array of molecules that can be ionized. In this study, we report on the assessment of liquid chromatography coupled to dielectric barrier discharge ionization with mass spectrometry for neutral lipid analysis. A set of different neutral lipid subclasses (triacylglycerides, diacylglycerides, and sterols) were selected for the study. The main species detected from our ionization source were [M-H2 O+H]+ , [M+H]+ or [M-R-H2 O+H]+ , attributed to sterol dehydration, protonation or the fragmentation of an acyl chain accompanied by a water loss of the glycerolipids, respectively. In terms of sensitivity, the dielectric barrier discharge displayed overall improved abundances and comparable or better limits of quantitation than atmospheric pressure chemical ionization for both acylglycerols and sterols. As a case study, different archaeological samples with variable content in neutral lipids, particularly triacylglycerides, were studied. The identification was carried out by combining accurate mass and the tentative formula associated with the exact mass, retention time matching with standards, and additional structural information from in-source fragmentation. The high degree of unsaturation and the presence of sterols revealed the potential vegetal origin of the material stored in the analyzed samples.


Assuntos
Pressão Atmosférica , Esteróis , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Espectrometria de Massas , Espectrometria de Massas por Ionização por Electrospray
10.
Anal Chim Acta ; 1179: 338835, 2021 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-34535252

RESUMO

Although electron impact ionization (EI) remains the standard ionization source for GC-MS, it presents extensive fragmentation as its main limitation. The potential of a novel plasma-based soft ionization source named controlled-atmosphere flexible microtube plasma (CA-FµTP) has been evaluated in this work for the determination of monoaromatic volatile BTEX group (namely benzene, toluene, ethylbenzene, and o-, m- and p-xylenes) in olive oil, based on headspace technique. The obtained results show an attractive advantage over EI due to no fragmentation was observed. A nitrosated ion [M + NO]+ is obtained as the most abundant species. Thus, the BTEX mass spectrum identification can be carried out without major effort. In general, the sensitivity for CA-FµTP was comparable to those obtained by EI, achieving LODs ranged from 0.6 to 1.0 µg kg-1. The potential usefulness of GC-CA-FµTP-MS for the detection of BTEX was demonstrated by analyzing olive oil samples and identifying traces of these compounds in one sample. Therefore, the proposed plasma-based soft ionization is suitable for BTEX analysis in fatty complex matrixes as olive oil.


Assuntos
Derivados de Benzeno , Xilenos , Atmosfera , Benzeno/análise , Derivados de Benzeno/análise , Cromatografia Gasosa-Espectrometria de Massas , Espectrometria de Massas , Azeite de Oliva , Tolueno/análise , Xilenos/análise
11.
Food Chem ; 365: 130486, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34237571

RESUMO

After more than ten years since pesticide residues were detected in citrus-flavored soft drinks, this study reveals that the situation has not changed. A new sensitive multiresidue UHPLC-MS/MS method has been validated for 88 pesticides, which was used to analyze 200 samples manufactured in 67 countries, 80% corresponding to fruit-based soft drinks. The results show that 98% of the samples collected worldwide contained at least one pesticide, and 85% of them contained more than 4 pesticides. 40 out of 88 target compounds were quantified among the screened samples. Europe was the world region with the highest total amount of pesticides, probably due to the higher content of juice concentrate in samples, which may be the main source of the pesticide residues. Nevertheless, residues were also found in samples with no juice, so water quality also plays an important role as the main ingredient of citrus-flavored soft drinks.


Assuntos
Citrus , Resíduos de Praguicidas , Bebidas Gaseificadas/análise , Contaminação de Alimentos/análise , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem
12.
Food Chem ; 347: 129020, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-33482490

RESUMO

Datura species are well known because of their high concentration of tropane alkaloids, which has led to poisoning episodes when Datura is accidentally mixed with edible crops. Therefore, the European Union has set a maximum level in cereal-based infant food products of 1 µg kg-1 for atropine and scopolamine. However, the occurrence of these compounds in other commodities has become a global concern. Spinach and derived products can be contaminated with Datura innoxia leaves. In this study, we tested frozen spinachs and spinach-based infant food products. The determination was carried out by UHPLC-MS/MS after applying the QuEChERS method as sample treatment. The LOQs were below 0.016 µg kg-1, achieving satisfactory results in terms of precision, accuracy, and matrix effects. The obtained results (ranging between 0.02 and 8.19 µg kg-1) were close to the maximum level set by the European Union for 24% of the samples tested.


Assuntos
Atropina/análise , Cromatografia Líquida de Alta Pressão/métodos , Datura/química , Análise de Alimentos , Escopolamina/análise , Espectrometria de Massas em Tandem/métodos , Spinacia oleracea
13.
Anal Methods ; 12(40): 4831-4852, 2020 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-33000770

RESUMO

Ambient mass spectrometry refers to the family of techniques that allows ions to be generated from condensed phase samples under ambient conditions and then, collected and analysed by mass spectrometry. One of their key advantages relies on their ability to allow the analysis of samples with minimal to no sample workup. This feature maps well to the requirements of food safety testing, in particular, those related to the fast determination of pesticide residues in foods. This review discusses the application of different ambient ionization methods for the qualitative and (semi)quantitative determination of pesticides in foods, with the focus on different specific methods used and their ionization mechanisms. More popular techniques used are those commercially available including desorption electrospray ionization (DESI-MS), direct analysis on real time (DART-MS), paper spray (PS-MS) and low-temperature plasma (LTP-MS). Several applications described with ambient MS have reported limits of quantitation approaching those of reference methods, typically based on LC-MS and generic sample extraction procedures. Some of them have been combined with portable mass spectrometers thus allowing "in situ" analysis. In addition, these techniques have the ability to map surfaces (ambient MS imaging) to unravel the distribution of agrochemicals on crops.


Assuntos
Resíduos de Praguicidas , Praguicidas , Agroquímicos/análise , Frutas/química , Espectrometria de Massas , Resíduos de Praguicidas/análise
14.
Sci Total Environ ; 715: 137005, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32041002

RESUMO

The presence of pesticide residues in bees is of great interest, given the central role of bees as indicators for environmental assessment. The goal of this article is to propose a method to capture enhanced chemical information for these central environmental indicators. Most of the methods rely on the analysis of pooled samples rather than individual specimens due to practical sample preparation method considerations and limitations in sensitivity. This leads to miss information on the mapping of pesticides and actual amount of pesticide per specimen. In this article, a nanoflow liquid chromatography system coupled to high resolution mass spectrometry (using a hybrid quadrupole-Orbitrap instrument) has been applied for the development of a multiresidue pesticide method for the determination of 162 multiclass pesticides in specific part of honeybee samples (ca. abdomen, head or thorax). The reduced flow rate provided an enhancement in sensitivity and a strong reduction of matrix effects, thus only a quick and simple ultrasound assisted extraction using minute amount of sample was required. Satisfactory results were obtained for all tested analytes with concentration levels detected lower than 0.5 ng g-1 in all cases, thus being acceptable for monitoring purposes. Matrix effect was negligible for 94% of compounds. Extraction recoveries ranged from 70% to 105%, being within SANTE guidelines. Finally, the applicability of the method was demonstrated, by successful application to the analysis of contaminated honeybee samples, extracting useful information from specific bee parts of single specimens, thus, enabling pseudo spatially resolved chemical information.


Assuntos
Resíduos de Praguicidas/análise , Animais , Abelhas , Cromatografia Líquida , Espectrometria de Massas em Tandem
15.
Sci Total Environ ; 697: 134058, 2019 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-31487597

RESUMO

Emerging contaminants (ECs) such as pharmaceuticals, personal care products, drugs of abuse and polar pesticides are under particular attention due to their high consumption, frequent detection in the environment and reported ecotoxicological risk. This study investigates the occurrence and distribution of multiclass of ECs in surface waters at basin scale of two Atlantic coastal lagoons of Uruguay, South America. For this purpose, a target screening approach covering up to 362 compounds was employed using nanoflow liquid chromatography - high resolution mass spectrometry (nanoLC/HRMS). 56 compounds were identified including five banned pesticides in the European Union: atrazine, carbendazim, chlorpyrifos ethyl, diazinon, and ethion. Pharmaceuticals, hormones and drugs of abuse showed maximum detection frequencies and concentrations downstream cities. The highest occurrence of pesticides was found in lagoons and streams with neighboring agricultural activity. ECs were also found in coastal sea. Environmental risk assessment revealed that the hormones 17α-ethinylestradiol and 17-ß-estradiol showed the highest risk to aquatic organisms in these basins. This study represents the first basin- scale monitoring of ECs in superficial waters encompassing streams, lagoons, and coastal seas in Uruguay, South America.

16.
Anal Bioanal Chem ; 411(19): 4785-4796, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30707264

RESUMO

In this work, the multiclass detection of explosives and related compounds has been studied by liquid chromatography-high-resolution mass spectrometry by means of a time-of-flight mass spectrometer (TOFMS) operated in the negative ion mode, using dielectric barrier discharge ionization (DBDI). Reversed-phase high-performance liquid chromatography (HPLC) separation was performed using water-methanol mobile phase without any modifier, although the effect of ammonium acetate was studied. DBD plasma was generated by applying a square wave voltage of 2.5 kV to a 100-mL min-1 He flow. The DBDI probe was adjusted to fit the commercial API source housing so that the HPLC eluent was nebulized and vaporized in the same manner as for atmospheric-pressure chemical ionization (APCI). The ionization process was affected by the temperature of the two nitrogen streams used to vaporize the solvent and the analytes, particularly for RDX and HMX, which are thermolabile compounds. The best approach in terms of sensitivity for all the studied compounds was the use of a gradient of temperatures in the ionization source, starting at 225/200 °C (vaporizer/drying gas temp) for nitramines and ending at 350/325 °C for nitroaromatic compounds. High-resolution full-scan spectra of individual selected compounds were recorded by LC-DBDI-TOFMS, and the results were compared to LC-APCI-TOFMS. A better sensitivity (slope of calibration curve) was obtained by DBDI for more than 70% of the studied compounds in both wastewater and soil extracts. Graphical abstract ᅟ.

17.
Food Chem ; 279: 144-149, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30611473

RESUMO

A nanoflow liquid chromatography high resolution mass spectrometry method for the quantification of mycotoxins in nuts has been developed. Two strategies based on QuEChERS methodology were evaluated. Thus, EMR-lipid was compared with a conventional mixture of PSA and C18 dispersive solid phase extraction sorbents which have been commonly used in this type of matrices as sample clean-up. The results showed that the use of EMR-lipid reduced more effectively matrix components, achieving a negligible matrix effect for all mycotoxins studied in peanut, pistachio and almond. The proposed method was validated in line with SANTE guidelines using EMR-Lipid as dispersive solid phase extraction sorbent. The lowest concentration level were between 0.05 and 5 µg kg-1, being lower than the maximum levels established by the current legislation. Recovery rates ranged from 75% to 98% was obtained in all sample studied, achieving also satisfactory precision with RSD values lower than 19% in all cases.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Micotoxinas/análise , Nozes/química , Arachis/química , Arachis/metabolismo , Espectrometria de Massas , Micotoxinas/isolamento & purificação , Nanotecnologia , Nozes/metabolismo , Pistacia/química , Pistacia/metabolismo , Prunus dulcis/química , Prunus dulcis/metabolismo , Extração em Fase Sólida
18.
Anal Chem ; 91(5): 3733-3739, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30672695

RESUMO

Plasma sources in atmospheric pressure soft-ionization mass spectrometry have gained significant interest in recent years. As many of these sources are used under ambient air conditions, their interaction with the surrounding atmosphere plays an important role in the ionization pathway. This study focuses on the interaction between the plasma source and the surrounding atmosphere by connecting the plasma source to the mass spectrometer using a 2 mm ID closed reactant capillary supplied by a reactant gas up to 500 mL per minute to gain a controlled atmosphere. Different reactant gases (Ar, He, O2, and N2) and reactant gas mixtures are tested with regard to the DBDI performance and then used to improve the ionization efficiency. Tailoring the controlled atmosphere for a certain analyte, for example, perfluorinated compounds, leads to significantly improved limits of detection up to 2 ppb.

19.
Sci Total Environ ; 625: 1088-1092, 2018 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29996405

RESUMO

The spread of Datura sp. in European countries influences crop management and implies continuous food safety issues because of tropane alkaloids, atropine and scopolamine, the most relevant natural toxic compounds of this weed. These alkaloids can contaminate cereals to such a level that hampers food/feed related use and diverts batches of contaminated raw materials towards ultimate disposal such as burning. As no unambiguous information has been available on the fate of tropane alkaloids in soils, our study focused on the quantification and follow-up of these toxic residues in a soil experiment where the tropane alkaloids were mixed to the soil in the form of naturally contaminated unhulled millet in 1:40 millet:soil ratio - this approach provides a more realistic scenario compared to standard solution based spiking. To achieve accurate results, soil and millet extraction processes have been validated and a liquid chromatography - mass spectrometry set-up was addressed to provide selective and quantitative analysis. The initial concentration of atropine (75ngg-1) and scopolamine (47ngg-1) in the soil decreased with >90% in 15days and reached a high level of elimination (>97%) in 29days. This observation opens an option for the use of tropane contaminated millet or millet waste other than burning, as these toxic alkaloids can be significantly degraded in the soil system. On the other hand, the persistence of intact tropane alkaloids in soils might be questioned to the extent that calls the attention to the (re)assignment of their supposed allelopathic effects.


Assuntos
Atropina/análise , Monitoramento Ambiental , Escopolamina/análise , Poluentes do Solo/análise , Milhetes , Agricultura Orgânica , Solo/química
20.
Anal Chim Acta ; 1020: 76-85, 2018 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-29655430

RESUMO

Although electrospray ionization (ESI) remains the gold standard ionization source for LC-MS, it exhibits two main limitations: the occurrence of matrix effects and the limited ionization coverage towards nonpolar compounds. Dielectric barrier discharge ionization (DBDI) has gained attraction in recent years as a versatile ionization method in different applications and formats. Here, we report a thorough evaluation of DBDI as ionization interface for LC-MS, which reveals attractive advantages over ESI and atmospheric pressure chemical ionization (APCI) provided its singular ionization mechanism versatility. A suite of 80 pesticides across a wide range of physicochemical properties were selected and the results were compared with both ESI and APCI sources. Using a helium plasma operated in homogeneous regime with square-wave AC waveform and relatively low voltages (2.5 kV), not only DBDI was able to ionize compounds only amenable so far by GC-MS (eg. organochlorine species), but also offered a competitive performance in terms of sensitivity when contrasted with the commercial electrospray ionization source under equivalent conditions. Unlike ESI, DBDI mechanism occurs in the gas-phase, so the method is less affected by liquid-phase surface phenomena that yield ion suppression in ESI. Data collected in the positive ion mode revealed negligible matrix effect values (<10% suppression) for most of the studied compounds in different complex matrix extracts such as wastewater, orange or olive oil. This is also consistent with the absence of adduct formation whereas with ESI source, Na adduct formation is quite common with these species. In general, both sensitivity and average limits of quantitation for DBDI were similar to those obtained by ESI and better than APCI. Results showed that analyte coverage with DBDI is enhanced with respect to ESI and APCI sources being able to effectively analyze organochlorine compounds.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...